{"id":1219,"date":"2026-11-10T14:52:31","date_gmt":"2026-11-10T05:52:31","guid":{"rendered":"https:\/\/iupizeta.mgc.co.jp\/?post_type=column&#038;p=1219"},"modified":"2026-11-10T14:52:31","modified_gmt":"2026-11-10T05:52:31","slug":"cpo-optical-interconnect","status":"publish","type":"column","link":"https:\/\/iupizeta.mgc.co.jp\/en\/column\/cpo-optical-interconnect\/","title":{"rendered":"What is CPO? Optical connection components used in co-packaged optics"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\ud83d\udccc <strong>Three-point summary<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>CPO stands for co-packaged optics, a method in which the optical engine that converts between electrical and optical signals is mounted close to the ASIC, the semiconductor chip for switching, on the same package substrate.<\/li>\n\n\n\n<li>The aim is to shorten electrical wiring and reduce power consumption and signal loss, and the optical connection between the optical engine and optical fibers requires positioning accuracy, dimensional stability, and compatibility with the reflow process.<\/li>\n\n\n\n<li>The components that make up the optical connection are also subject to material selection, and optical resin can be one of the options.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">CPO is an abbreviation that means different things in different fields. The CPO covered in this article is co-packaged optics, used for optical communication in data centers. After organizing how CPO works, this article explains what components are used in the optical connection between the optical engine and optical fibers, and what is required of them.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1600\" height=\"1073\" src=\"https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/illust-cpo-optical-interconnect-en.png\" alt=\"Co-packaged optics: optical engines mounted close to the ASIC on the package substrate, connected by optical fibers to the front panel; inset shows FAU coupling to an optical engine\" class=\"wp-image-1369\" srcset=\"https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/illust-cpo-optical-interconnect-en.png 1600w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/illust-cpo-optical-interconnect-en-300x201.png 300w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/illust-cpo-optical-interconnect-en-1024x687.png 1024w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/illust-cpo-optical-interconnect-en-768x515.png 768w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/illust-cpo-optical-interconnect-en-1536x1030.png 1536w\" sizes=\"(max-width: 1600px) 100vw, 1600px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">What is CPO?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">CPO, short for co-packaged optics, is a method in which the optical engine, which converts between optical and electrical signals, is mounted close to the ASIC, the semiconductor chip for switching, on the same package substrate. Conventionally, a module called an optical transceiver was plugged into the front panel of the switch equipment and connected to the ASIC by electrical wiring on the board. In CPO, this optical conversion section is moved right next to the ASIC.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"2000\" height=\"1187\" src=\"https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_pluggable_vs_cpo_en.png\" alt=\"\" class=\"wp-image-1295\" srcset=\"https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_pluggable_vs_cpo_en.png 2000w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_pluggable_vs_cpo_en-300x178.png 300w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_pluggable_vs_cpo_en-1024x608.png 1024w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_pluggable_vs_cpo_en-768x456.png 768w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_pluggable_vs_cpo_en-1536x912.png 1536w\" sizes=\"(max-width: 2000px) 100vw, 2000px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Differences from pluggable optical transceivers<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The conventional method of plugging modules into the front panel is called pluggable (removable). The differences between the two methods are shown in the table below.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table>\n<colgroup>\n<col style=\"width: 33%\">\n<col style=\"width: 33%\">\n<col style=\"width: 33%\">\n<\/colgroup>\n<thead>\n<tr>\n<th>Item<\/th>\n<th>Pluggable optical transceiver<\/th>\n<th>CPO<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Position of the optical conversion section<\/td>\n<td>Plugged into the front panel<\/td>\n<td>Mounted close to the ASIC on the same package substrate<\/td>\n<\/tr>\n<tr>\n<td>Electrical wiring to the ASIC<\/td>\n<td>Routed for several inches on the board<\/td>\n<td>Shortened<\/td>\n<\/tr>\n<tr>\n<td>Ease of replacement<\/td>\n<td>Easy to replace<\/td>\n<td>Difficult to replace because it is built into the equipment<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Components inside optical transceivers are also explained in our article \u201c<a href=\"https:\/\/iupizeta.mgc.co.jp\/en\/column\/optical-transceiver-resin\/\">Can optical transceiver components be made from resin? The barrier posed by glass and ceramics<\/a>\u201d.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Why CPO is attracting attention<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Electrical wiring length and power consumption<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">With growing data demand, the total bandwidth of switch systems has been reported to double every two to three years. In electrical wiring that sends large volumes of data at high frequencies, the longer the wiring, the more noticeable the signal degradation, and the power needed to maintain quality tends to increase.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">CPO is a method that reduces signal loss and power consumption by shortening the electrical wiring between the ASIC and the optical engine. Reports put the energy consumed per bit at about 15\u201320 pJ\/bit for the pluggable method and about 5\u201310 pJ\/bit for CPO. These values vary with measurement conditions and configuration.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Bandwidth density at the front panel<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">In the pluggable method, optical transceivers are lined up along the edge of the front panel. The number of modules that can be lined up on the front and the heat concentrated at the front become constraints on equipment design. Because CPO places the optical engine near the ASIC, pluggable slots are no longer needed, and the freedom of front-panel layout is said to increase.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"2450\" height=\"1514\" src=\"https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_background_en.png\" alt=\"\" class=\"wp-image-1296\" srcset=\"https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_background_en.png 2450w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_background_en-300x185.png 300w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_background_en-1024x633.png 1024w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_background_en-768x475.png 768w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_background_en-1536x949.png 1536w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_background_en-2048x1266.png 2048w\" sizes=\"(max-width: 2450px) 100vw, 2450px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">CPO configuration and the optical connection<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Mounting of the optical engine and switch ASIC<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">CPO mounting structures are classified as 2D, in which the ASIC and optical chips are placed side by side on the substrate; 2.5D, in which they are connected through an interposer made of silicon or similar materials; and 3D, in which they are stacked and connected vertically. Because 3D can reduce the parasitics and spacing of electrical connections, it is cited as a direction for higher bandwidth.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In 2023, the industry organization OIF published an implementation agreement for 51.2 Tb\/s switches that assumes a configuration in which 16 optical engine modules of 3.2 Tb\/s each are arranged near the ASIC. The modules are mounted in sockets on the substrate, and heat is transferred from a heat spreader attached to the top surface, through a thermal interface material, to the cooling component.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">External light source and fiber connection<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The laser that supplies light to the optical engine can be placed either inside the module or outside it. Placing it outside is regarded as a way to reduce heat generation in the optical engine. In the OIF implementation agreement for the 3.2T module, four or eight polarization-maintaining fibers, in ribbon or bundled form, connect the external light source to the optical engine.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The external light source is standardized in a separate implementation agreement (ELSFP) as a module plugged into the front panel. It connects through a multi-fiber blind-mate optical connector on the back of the module (a multi-fiber connector that mates simply by being pushed in once aligned), and the aims are to place the laser at a low-temperature position on the front panel and to allow replacement in the field when needed. Challenges cited for the external light source method include low coupling efficiency, the difficulty of designing the optical connection, and fiber burn damage at high output power.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The optical engine module has a pigtail (a lead-out optical fiber) of 5 cm or longer. Examples are shown in which the pigtail is connected with MPO-type connectors to a bulkhead adapter inside the equipment or to the front panel, but the connector itself is not specified in the implementation agreement.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"2000\" height=\"1150\" src=\"https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_optical_path_en.png\" alt=\"\" class=\"wp-image-1297\" srcset=\"https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_optical_path_en.png 2000w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_optical_path_en-300x173.png 300w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_optical_path_en-1024x589.png 1024w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_optical_path_en-768x442.png 768w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_optical_path_en-1536x883.png 1536w\" sizes=\"(max-width: 2000px) 100vw, 2000px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Coupling between the optical engine and fibers<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The part that connects the optical waveguide on the optical engine to optical fibers has different characteristics depending on the coupling method.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Grating coupler<\/strong>: A method that inputs and outputs light vertically from the top surface of the substrate. Its usable bandwidth is limited, it is susceptible to manufacturing variation and polarization, and achieving coupling loss below 1 dB is said to be difficult.<\/li>\n\n\n\n<li><strong>Edge coupler<\/strong>: A method that couples light at the edge face of the substrate. It offers low coupling loss and a wide usable bandwidth, but processing is difficult, and there are challenges in stability and reliability.<\/li>\n\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"2000\" height=\"1150\" src=\"https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_coupler_en.png\" alt=\"\" class=\"wp-image-1298\" srcset=\"https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_coupler_en.png 2000w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_coupler_en-300x173.png 300w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_coupler_en-1024x589.png 1024w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_coupler_en-768x442.png 768w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_coupler_en-1536x883.png 1536w\" sizes=\"(max-width: 2000px) 100vw, 2000px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Research is also under way on building detachable optical connections using an FAU (fiber array unit), which arranges and holds optical fibers, and a microlens array, in which tiny lenses are arranged on a surface. Coupling loss below 1 dB has been reported for a detachable interface using a microlens array.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">FAUs and microlens arrays are also explained in our articles \u201c<a href=\"https:\/\/iupizeta.mgc.co.jp\/en\/column\/silicon-photonics\/\">What is silicon photonics? The basics of the technology supporting optical communication<\/a>\u201d and \u201c<a href=\"https:\/\/iupizeta.mgc.co.jp\/en\/column\/micro-lens-array\/\">What is a microlens array? How it works, applications, and manufacturing methods explained<\/a>\u201d.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Optical connectors and their components are explained in detail in each of the following articles.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/iupizeta.mgc.co.jp\/en\/column\/optical-connector-types\/\">Types of optical connectors and the components used<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/iupizeta.mgc.co.jp\/en\/column\/mt-ferrule-mpo\/\">MT ferrules and MPO connectors<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/iupizeta.mgc.co.jp\/en\/column\/ferrule-material\/\">Ferrule material comparison<\/a><\/li>\n\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Properties required of optical connection components<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Positioning accuracy and dimensional stability<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Aligning optical fibers requires accuracy on the order of a few \u03bcm. Dimensions that hardly change with temperature are an important condition for components that hold optical fibers.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Around the CPO substrate, differences in thermal expansion between materials have been pointed out as a challenge. It has been reported that organic substrates have a large coefficient of thermal expansion (CTE) and face challenges in dimensional stability, that glass has a CTE close to that of silicon and printed circuit boards and can reduce stress, and that differences in thermal expansion between mold resin and other materials cause warpage and chip shift. Differences in thermal expansion from surrounding materials are also a point to check when selecting components for the optical connection.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">CTE is also explained in our article \u201c<a href=\"https:\/\/iupizeta.mgc.co.jp\/en\/column\/cte\/\">What Is Coefficient of Thermal Expansion (CTE)? Thermal Expansion and Dimensional Design of Optical Resins<\/a>\u201d.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Relationship with the reflow process<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The temperature of the reflow process, in which the optical engine and sockets are soldered to the board, is said to reach the upper 200\u00b0C range with lead-free solder. If components of the optical connection are exposed to this temperature, there is a risk of softening and deformation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As countermeasures, detachable connection methods that allow optical fibers to be attached after the reflow process, and detachable interfaces compatible with the reflow process, have been reported. For details on reflow heat resistance, see our article \u201c<a href=\"https:\/\/iupizeta.mgc.co.jp\/en\/column\/optical-transceiver-resin\/\">Can optical transceiver components be made from resin? The barrier posed by glass and ceramics<\/a>\u201d.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Maintainability and heat management<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Because CPO is built into the equipment, replacement as in the pluggable method becomes difficult, and operating practices are said to need review. Mounting in sockets is one structural approach to this challenge.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Components of the optical connection may be required to have dimensional accuracy that withstands repeated attachment and detachment, and shape stability in environments with heat generation.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"2450\" height=\"1853\" src=\"https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_requirements_en.png\" alt=\"\" class=\"wp-image-1299\" srcset=\"https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_requirements_en.png 2450w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_requirements_en-300x227.png 300w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_requirements_en-1024x774.png 1024w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_requirements_en-768x581.png 768w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_requirements_en-1536x1162.png 1536w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_requirements_en-2048x1549.png 2048w\" sizes=\"(max-width: 2450px) 100vw, 2450px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Applicability of Iupizeta EP<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In the field of optical resins, the balance between refractive index and heat resistance (glass transition temperature, Tg) is important. The standard grades (EP-4500 to EP-9000) of Mitsubishi Gas Chemical\u2019s optical resin \u201cIupizeta EP\u201d have a Tg of 140\u2013145\u00b0C, which is below the temperature of the reflow process. This can therefore be a constraint for components that require reflow compatibility.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As part of proposing materials suited to each application, Mitsubishi Gas Chemical is currently investigating development materials with higher heat resistance. For example, it is developing resins with the following properties.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Development material A: refractive index nd = 1.61, Tg = 264\u00b0C<\/li>\n\n\n\n<li>Development material B: refractive index nd = 1.63, Tg = 280\u00b0C<\/li>\n\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Both show high internal transmittance in the 1310 nm and 1550 nm bands widely used in optical communication, and their features are smaller dimensional change due to water absorption and lower birefringence than thermoplastic polyimide and polyetherimide. Their CTE is still large compared with quartz glass and ceramics, so investigations to lower the CTE further are also under way.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"2450\" height=\"1981\" src=\"https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_ep_dev_en.png\" alt=\"\" class=\"wp-image-1300\" srcset=\"https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_ep_dev_en.png 2450w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_ep_dev_en-300x243.png 300w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_ep_dev_en-1024x828.png 1024w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_ep_dev_en-768x621.png 768w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_ep_dev_en-1536x1242.png 1536w, https:\/\/iupizeta.mgc.co.jp\/cms\/wp-content\/uploads\/2026\/11\/fig_ep_dev_en-2048x1656.png 2048w\" sizes=\"(max-width: 2450px) 100vw, 2450px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Anticipated applications include lens holding components, fixing and integrated components for optical members, and resin components around housings. For details on applicability and conditions for optical communication components, including CPO, please reach out to us individually based on your required specifications.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Summary: CPO and optical connection components<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">CPO is a method that mounts the optical engine close to the switch ASIC and shortens the electrical wiring to reduce power consumption and signal loss. The optical connection between the optical engine and optical fibers involves conditions such as fiber connection to the external light source, coupling with the optical engine, positioning accuracy, dimensional stability, reflow process compatibility, and maintainability.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">These conditions also extend to material selection for the components that make up the optical connection. Optical resins such as Iupizeta EP can be one of those options.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For details on Iupizeta EP, please reach out through the <a href=\"https:\/\/iupizeta.mgc.co.jp\/en\/\">Iupizeta EP official website<\/a>.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Some images and text in this article were created with the help of generative AI.<\/p>\n\n","protected":false},"featured_media":1212,"template":"","meta":{"_acf_changed":false,"_locale":"en_US","_original_post":"https:\/\/iupizeta.mgc.co.jp\/?post_type=column&p=1211"},"column_tax":[52],"class_list":["post-1219","column","type-column","status-publish","has-post-thumbnail","hentry","column_tax-basics","en-US"],"acf":[],"_links":{"self":[{"href":"https:\/\/iupizeta.mgc.co.jp\/wp-json\/wp\/v2\/column\/1219","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/iupizeta.mgc.co.jp\/wp-json\/wp\/v2\/column"}],"about":[{"href":"https:\/\/iupizeta.mgc.co.jp\/wp-json\/wp\/v2\/types\/column"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/iupizeta.mgc.co.jp\/wp-json\/wp\/v2\/media\/1212"}],"wp:attachment":[{"href":"https:\/\/iupizeta.mgc.co.jp\/wp-json\/wp\/v2\/media?parent=1219"}],"wp:term":[{"taxonomy":"column_tax","embeddable":true,"href":"https:\/\/iupizeta.mgc.co.jp\/wp-json\/wp\/v2\/column_tax?post=1219"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}